Experimental demonstration and optimization of X-ray StaticCodeCT

dc.contributor.authorCuadros, Angela P.
dc.contributor.authorLiu, Xiaokang
dc.contributor.authorParsons, Paul E.
dc.contributor.authorMa, Xu
dc.contributor.authorArce, Gonzalo R.
dc.date.accessioned2022-02-02T14:36:43Z
dc.date.available2022-02-02T14:36:43Z
dc.date.issued2021-10-18
dc.descriptionThis article was originally published in Applied Optics. The version of record is available at: https://doi.org/10.1364/AO.438727en_US
dc.description.abstractAs the use of X-ray computed tomography (CT) grows in medical diagnosis, so does the concern for the harm a radiation dose can cause and the biological risks it represents. StaticCodeCT is a new low-dose imaging architecture that uses a single-static coded aperture (CA) in a CT gantry. It exploits the highly correlated data in the projection domain to estimate the unobserved measurements on the detector. We previously analyzed the StaticCodeCT system by emulating the effect of the coded mask on experimental CT data. In contrast, this manuscript presents test-bed reconstructions using an experimental cone-beam X-ray CT system with a CA holder. We analyzed the reconstruction quality using three different techniques to manufacture the CAs: metal additive manufacturing, cold casting, and ceramic additive manufacturing. Furthermore, we propose an optimization method to design the CA pattern based on the algorithm developed for the measurement estimation. The obtained results point to the possibility of the real deployment of StaticCodeCT systems in practice.en_US
dc.description.sponsorshipNational Science Foundation (CIF 171757); University of Delaware (BlueHen Proof of Concept Grant, UNIDEL).en_US
dc.identifier.citationAngela P. Cuadros, Xiaokang Liu, Paul E. Parsons, Xu Ma, and Gonzalo R. Arce, "Experimental demonstration and optimization of X-ray StaticCodeCT," Appl. Opt. 60, 9543-9552 (2021)en_US
dc.identifier.issn2155-3165
dc.identifier.urihttps://udspace.udel.edu/handle/19716/30234
dc.language.isoen_USen_US
dc.publisherApplied Opticsen_US
dc.titleExperimental demonstration and optimization of X-ray StaticCodeCTen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Experimental demonstration and optimization of.pdf
Size:
35.37 MB
Format:
Adobe Portable Document Format
Description:
Main article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
124 B
Format:
Item-specific license agreed upon to submission
Description: